Parameters
|
ВГТ-УЭТМ®-1А1-220
|
1
|
Rated voltage, kV
|
220
|
2
|
Max operating voltage, kV
|
252
|
3
|
Rated current, A
|
3150
по заказу возможно 4000
|
4
|
Rated breaking current, kA
|
40
|
5
|
Rated aperiodic component, %, maximum
|
47
|
6
|
Rated through short-circuit current, kA:
|
Peak (electrical endurance);
|
100
|
Root-mean-square current value during its flow (thermal stability current);
|
40
|
Thermal stability current time, s.
|
3
|
7
|
Rated parameters of making current, kA:
|
Peak;
|
100
|
Initial value of periodic component.
|
40
|
8
|
Commutation of capacitive current (class С1):
|
Rated commutation current of unloaded air line, А;
|
125
|
Rated commutation current of cable line, А;
|
250
|
Rated commutation current of single capacitor bank, А.
|
400
|
9
|
Rated breaking current of shunt reactor, А
|
315±63
|
10
|
Minimum breaking current of shunt reactor, А
|
100±20
|
11
|
Own breaking time, s
|
0,018…0,025
|
12
|
Total breaking time, s
|
0,050
|
13
|
Own making time, s, max
|
0,070
|
14
|
Diversity of poles operation, s, max
|
At making
|
0,005
|
At breaking
|
0,0033
|
15
|
Annual gas leakage rate, % of gas mass, max
|
0,5
|
16
|
Test lightning impulse, kV:To earth / between open contacts |
900 / 900 / 1050
|
17
|
Testing one-minute voltage of commercial frequency, kV:To earth / between open contacts |
440 / 440 / 440
|
18
|
Rated DC voltage of the drive control magnets, V |
=110 или = 220
|
19
|
Number of control magnets:
|
making
|
1
|
breaking
|
2
|
20
|
Operating voltage range of control magnets, % of the nominal value:
|
Making magnet
|
80-110
|
Breaking magnet
|
70-110
|
21
|
Rated value of the set DC consumed by magnets, А, max:
|
at 110V
|
5
|
at 220V
|
2,5
|
22
|
Number of contacts for auxiliary circuits (for the drive) |
14НО + 14НЗ + 2 проскальзывающих
|
23
|
Breaking current of commutation contacts for auxiliary circuits at 110/220 V, A:
|
AC
|
25
|
DC
|
4/2
|
24
|
Spring wind up motor power for making springs, kW
|
2х1,175
|
25
|
Rated voltage of feeding single-phase AC/DC motor of making springs, V
|
=110, = 220 или ~230
|
26
|
Time of making springs winding up, s, max
|
15
|
27
|
Rated capacity of drive heaters, W:
|
Continuous anti-condensate heating;
|
50
|
Main heating automatically shuts down at lower temperature
|
600
|
28
|
AC voltage of feeding heaters, V
|
230
|
29
|
Max vertical dynamic force on foundation of one of four support plates of the pole at operation (w/o own weight), кН:
|
Up
|
36,6
|
Down
|
27,8
|
30
|
Max static load on foundation of one of four support plates of the pole, kN
|
5,2
|
31
|
Static resultant force from cables and wind load in three perpendicular directions (А/В/С GOST R 52565), Н
|
2550 / 2300 / 1250
|
32
|
Weight of circuit breaker without metal support, kg, maximum:
|
|
Three-pole version
|
3500
|
|
Single-pole version
|
4650
|
2. Cycles and Operations of Circuit Breakers:
Breaking (О);
Making (В);
Making-breaking (ВО) including – without intended delay between operations (В) and (О);
Breaking - making (ОВ) at any contact-free pause;
Breaking – making - breaking (ОВО) with intervals between operations according to items 3 & 4;
Commutation cycles:
О - 0,3с – ВО - 180с - ВО;
О - 0,3с – ВО - 20с - ВО;
О - 180с – ВО - 180с – ВО.
3. Permissible breaking operations number for each pole without review and maintenance of arc chutes (commutation stability lifespan) at short-circuit currents and load currents:
At the current 100% of the rated breaking current: 17 operations
At the current 60 % of the rated breaking current: 45 operations
At the operating currents equal to the rated current: 5000 operations «Making-random pause-breaking».
Permissible number of making operations for short-circuit currents should be not more than 50% of the permissible breaking operations; permissible making operations at load currents is equal to permissible breaking operations.
4. Reliability of Circuit Breakers:
Mechanical strength before overhaul maintenance: 10000 operations «Making –random pause - breaking» with no current in the main circuit;
Lifespan before the first maintenance at least 25 years, provided that mechanical strength or communication stability life was not spent. Maintenance necessity is judged by diagnostics of the circuit breaker technical condition;
Circuit breaker lifespan before retirement at least 40 years.
5. Absolute pressure of gas brought to temperature plus 20°С, MPa
Versions Т1 and У1
|
Versions ХЛ1*
|
|
Filling pressure (nominal)
|
0,5
|
0,7
|
Warning alarm pressure
|
0,44
|
0,62
|
Lock pressure
|
0,42
|
0,6
|
6. Gas weight required for filling a circuit breaker, kg
|
Versions Т1 and У1
|
Для исполнения ХЛ1*
|
|
SF6 gas
|
Элегаз
|
Тетрафторметан
|
ВГТ-УЭТМ®-1А1-220
|
20,5
|
14,0
|
8,2
|