/fs/cache/a2/af/93/d0/5601951ea5a0daf50cc9f9af.jpg

ВАБ-UEТМ®-55-2500

Circuit breakers WAB-UETM®-55-2500/30-L-U2, WAB-UETM®-55-2500/30-P-U2, WAB-UETM®-55-2500/30-E-U2 are designed to protect the equipment of DC main electric locomotives against overloads and short-circuit currents.

Parameters

Parameters

Norms

WAB-UETM®-55-2500/30-Л- У2

WAB-UETM®-55-2500/30-П- У2

WAB-UETM®-55-2500/30-Э- У2

1. Main circuit current

DC

2. Polarization

Non-polarized

3.Drive type

Pneumatic

Electromagnetic

4. Rated voltage of the main circuit, V

3000

5. Maximum operating voltage, V

4100

6. Rated current at a constant load in time, A

2500

7. Nominal DC voltage of control circuits, V

50 or 110

110

8. Current limits of the setpoint, A

2000…3500

9. Breaking capacity of circuit breakers with inductance 5-15 mH, А:

30000

10. The smallest switchable current, A

8

11. Own opening time, s

0,004

12. The number of current cuts of 15000 A with an inductance of 15 mH without stripping the main contacts and the arc chute

300

13. The number of on and off in the absence of current in the main circuit, cycles

 

20000

50000

14. Weight of circuit breakers without spare parts, kg, not more

165

180

15. Service life of the circuit breaker, years

23

Write us

Your message has been send succesfully!
logo

Акционерное Общество "Уралэлектротяжмаш"

Yekaterinburg,
Frontovyh brigad, 22
+7 (343) 324-52-00
secretary@uetm.ru