Circuit breakers WAB-UETM®-55-2500/30-L-U2, WAB-UETM®-55-2500/30-P-U2, WAB-UETM®-55-2500/30-E-U2 are designed to protect the equipment of DC main electric locomotives against overloads and short-circuit currents.
Circuit breakers WAB-UETM®-55-2500/30-L-U2, WAB-UETM®-55-2500/30-P-U2, WAB-UETM®-55-2500/30-E-U2 are designed to protect the equipment of DC main electric locomotives against overloads and short-circuit currents.
Parameters |
Norms |
|||
WAB-UETM®-55-2500/30-Л- У2 |
WAB-UETM®-55-2500/30-П- У2 |
WAB-UETM®-55-2500/30-Э- У2 |
||
1. Main circuit current |
DC |
|||
2. Polarization |
Non-polarized |
|||
3.Drive type |
Pneumatic |
Electromagnetic |
||
4. Rated voltage of the main circuit, V |
3000 |
|||
5. Maximum operating voltage, V |
4100 |
|||
6. Rated current at a constant load in time, A |
2500 |
|||
7. Nominal DC voltage of control circuits, V |
50 or 110 |
110 |
||
8. Current limits of the setpoint, A |
2000…3500 |
|||
9. Breaking capacity of circuit breakers with inductance 5-15 mH, А: |
30000 |
|||
10. The smallest switchable current, A |
8 |
|||
11. Own opening time, s |
0,004 |
|||
12. The number of current cuts of 15000 A with an inductance of 15 mH without stripping the main contacts and the arc chute |
300 |
|||
13. The number of on and off in the absence of current in the main circuit, cycles |
20000 |
50000 |
||
14. Weight of circuit breakers without spare parts, kg, not more |
165 |
180 |
||
15. Service life of the circuit breaker, years |
23 |
UETM